32) Colón, L. A.*; Cintrón, J. M.; Anspach, J. A.; Fermier, A. M.; Swinney, K. A., "Very High Pressure HPLC with 1 mm i.d. Columns," Analyst, 2004, 129, 503-504.
31) Maloney, T. D.; Colón, L. A.*, "Comparison of Column Packing Techniques for Capillary Electrochromatography," J. Sep. Sci. 2002, 25, 1215-1225. pdf
30) Anurag S. Rathore, A. S.; Reynolds, K. J.; Colón, L. A.,* "Migration of ions through open and packed capillaries in capillary electrophoresis and electrochromatography," Electrophoresis 2002, 23, 2918-2928. pdf
29) Cintrón, J. M.; Colón, L. A.*, "Organo-silica nano-particles used in ultrahigh-pressure liquid chromatography," Analyst 2002, 127, 701-704. pdf
28) Rodríguez, S. A.; Colón, L. A.* , "29Si-NMR Studies of the Sol-Gel Hybrid Solution Containing Octadecyltriethoxysilane and Tetraethoxysilane Used to Fabricate a Stationary Phase for Open Tubular Capillary Electrochromatography," Appl. Spectrosc. 2001, 55, 472-480.
27) Colón, L. A.*; Burgos, G.; Maloney, T.D.; Cintrón, J.M.; Rodríguez, R.L., "Recent Progress in Capillary Electrochromatography," Electrophoresis 2000, 21, 3965-3993. pdf
26) Colón, L.A.;* Maloney, T.D.; Fermier, A.M., "Packing Columns for Capillary Electrochromatography," J. Chromatogr. A 2000, 887, 43-53. pdf
25) Reynolds, K. J.; Colón, L. A.*, "Submicron-Sized Organo-Silica Spheres for Capillary Electrochromatography," J. Liq. Chromatogr Relat. Tech. 2000, 21,161-173.
24) Burke, E. M.; Gou, Y.; Colón, L.; Rahima, M.; Veis, A.; Nancollas, G.H.*, "Influence of Polyaspartic Acid and Phosphophoryn on Octacalcium Phosphate Growth Kinetics," Colloids Surf. B: Biointerfaces 2000, 17, 49-57. pdf
23) Colón, L. A. *; Reynolds, K. J.; Burgos, G.; Maloney, T.D.; Lopez, J.,"Studies of Submicron Particles and Electroosmotic Flow in Packed Capillary Columns for CEC," Chromatography 1999, 20, 305-307.
22) Maloney, T. D.; Colón, L. A.*, "A Drying-Step in the Protocol to Pack Capillary Columns by Centripetal Forces for Capillary Electrochromatography," Electrophoresis 1999, 20, 2360-2365. pdf
21) Rodriguez, S. A.; Colón, L. A.*, "Investigations of a Sol-Gel Derived Stationary Phase for Open Tubular Capillary Electrochromatography," Anal. Chim. Acta 1999, 397, 207-215. pdf
20) Alicea-Maldonado, R.; Colón, L. A.*, "Capillary Electrochromatography Using a Fluoropolymer as the Chromatographic Support Material," Electrophoresis 1999, 20, 37-42. pdf
19) Rodriguez, S. A.; Colón, L. A.*, "Study of the Solution in the Synthesis of a Sol-Gel Composite Used as a Chromatographic Phase," Chem. Mater. 1999, 11, 754-762. pdf
18) Frerichs, V.; Colón, L. A.*, "Determination of Glucose by CE-LIF in Transdermally Collected Samples," Electrophoresis 1998, 19, 2625-2629.
17) Reynolds, K. J.; Maloney, T. D.; Fermier, A. M.; Colón, L. A.*, "Capillary Electrochromatography in Columns Packed by Gravity. Preliminary Study," Analyst 1998, 123, 1493-1495. pdf
16) Fermier, A. M.; Colón, L. A.*, "Capillary Electrochromatography in Columns Packed by Centripetal Forces," J. Microcol. Sep. 1998, 10, 439-447. pdf
15) Colón, L. A.*; Reynolds, K. J.; Alicea-Maldonado, R.; Fermier, A. M., "Advances in Capillary Electrochromatography," Electrophoresis 1997, 18, 2162-2174. (REVIEW)
14) Sun, S.; Heitz, M. P.; Perez, S. A.; Colón, L. A.; Bruckenstein, S.; Bright, F. V.*, "6-Propionyl-2-(N,N-dimethylamino)naphthalene (PRODAN) Revisited," Appl. Spectrosc. 1997, 51, 1316-1322.
13) Colón, L. A.*; Guo, Y.; Fermier, A. M., " Capillary Electrochromatography," Anal. Chem. 1997, 69, 461A-467A. (MADE THE COVER OF THE ISSUE)
12) Narang, P.; Colón, L. A.*, "Sol-Gel Derived Fluorinated Stationary Phase for Open Tubular Electrochromatography," J. Chromatogr. A 1997, 773, 65-72. pdf
11) Jordan, J. D.; Dunbar, R. A.; Hook, D. J.; Zhuang, H.; Gardella, J. A., Jr.; Colón, L. A.; Bright, F. V.*, "Characterization of Aerosol-Deposited Sol-Gel Derived Thin Films," Chem. Mater. 1998, 10, 1041-1051. pdf
10) Jin, Z.; Chen, R.; Colón, L. A.*, "Determination of Glucose in Submicroliter Samples by CE-LIF Using Pre-Column or On-Column Enzymatic Reactions," Anal. Chem. 1997, 69,1326-1331. pdf
9) Guo, Y.; Colón, L. A.*, "Open Tubular Liquid Chromatography Using a Sol-Gel Derived Stationary Phase," Chromatographia 1996, 43, 477-483.
8) Chen, R.; Jin, Z.; Colón, L. A.*, "Analysis of Tear Fluid by CE/LIF: A Non-Invasive Approach for Glucose Monitoring," J. Capillary Electrophor. 1996, 3, 243-248.
7) Fermier, A. M.; Colón, L. A.*, "Capillary Electrophoresis with Constant Potential Amperometric Detection Using a Nickel Microelectrode for Detection of Carbohydrates," J. High Resolu. Chromatogr. 1996, 19, 613-6 16.
6) Guo, Y.; Imahori, G. A.; Colón, L. A.*, "Hydrolytically Stable Amino-Silica Coating Material for Manipulation of the Electroosmotic Flow in Capillary Electrophoresis," J. Chromatogr. A 1996, 744, 17-29. pdf
5) Fermier, A. M.; Gostkowski; Colón, L. A.*, "Rudimentary Capillary-Electrode Alignment for Capillary Electrophoresis with Electrochemical Detection," Anal. Chem. 1996, 68, 1661-1664. pdf
4) Perez, S. A.; Colón, L. A.*, "Determination of Carbohydrates as Their Dansylhydrazine Derivatives by Capillary Electrophoresis with Laser-Induced Fluorescence," Electrophoresis 1996, 17, 352-358.
3) Guo, Y.; Colón, L. A.*, "Modification of the Inner Capillary Surface by the Sol-Gel Method: Application to Open Tubular Electrochromatography," J. Microcol. Sep. 1995, 7, 485-491.
2) Guo, Y.; Colón, L. A.*, "A Stationary Phase for Open Tubular Liquid Chromatography and Electrochromatography Using Sol-gel Technology," Anal. Chem.1995 , 67, 2511-2516. pdf
1) Guo, Y.; Colón, L. A.*; Dadoo, R.; Zare, R. N., "Analysis of Underivatized Amino Acids by Capillary Electrophoresis Using Constant Potential Amperometric Detection," Electrophoresis 1995, 16, 493-497.
Patents
4) Colón, L. A.; Hoth, D. C., "Group IV Monolihtic Columns," Patent application: U.S. Serial No. 60/551,471 on March 9, 2004.
3) Colón, L. A.; Fermier, A. M.; Sagerman, G. R., "Method and Device for packing Capillary Columns," U.S. Patent 6,095,202, 2000. USPTO
2) Bright, F. V.; Colón, L. A.; Jordan, J. D.; Dunbar, R. A., "Aerosol Generated Sol-Gel Derived Thin Film and Applications Thereof," U.S. Patent 6,016,689, 2000. USPTO
1) Colón, L. A., "Silica Materials," U.S. Patent 5,869,152, 1999. USPTO
Book Chapters
5) Colón, L. A.*; Maloney, T.D.; Anspach, J.; Colón, H., "Column Technology for Capillary Electrochromatography." in Advances in Chromatography, Chapter 2, Volume 42, pp. 43-106.
4) Colón, L. A.*; Baird, L.J., "Detectors in Modern Gas Chromatography." in Modern Practice of Gas Chromatography , 4th ed., Grob, R. and Barry, E.F., Eds., Wiley, 2004; Chapter 6.
3) Colón, L. A.*; Maloney, T. D.; Fermier, A. M. , "Packed Beds for Capillary Electrochromatography," in Capillary Electrochromatography, Deyl, Z.; Svec, F., Eds., Elsevier: New York, 2001; Chapter 4, pp. 111-164.
2) Colón, L. A.*, "Sol-Gel Derived Materials for Analytical Separations," In Science and Technology of Polymers and Advanced Materials: Emerging Technologies and Business Opportunities, Ed. Prasad, P.N.; Mark, J.E.; Kandil, S.H. ; Kafafi, Z.H.; Plenum, 1998; pp. 835-844.
1) Colón, L. A.*, "Analysis of Body Fluids: Urine, Blood, Saliva, and Tears," In Handbook of Capillary Electrophoresis Applications, Shintani, H.; Polonski, J., Eds.; Blackie Academic and Professional: London, 1997; Chapt er 32, pp 486-498.